Time: 2023-01-09
Signal acquisition board
Support multiple input signals: 6 analog signals+10 switching signals can be collected
Multiple signals can be output: RS232, RS485, RS422, CAN, USB single or multiple combinations
Multiple protocols can be implemented: SENTOP, Modbus, CANopen, FS HID (USB) and customization protocol

Protection degree
IP40
Installation mode
4xM3 Fixing nail
Mass
Approx.300g
Housing material
Anodized aluminium alloy
Operating temperature range
-20℃~+70℃
Storage temperature range
-20℃~+70℃
EFT
IEC61000-4-4 Level 4
SURGE
IEC61000-4-5 Level 4
ESD durability
Contact discharge ±8KV,Aerial discharge ±15KV,EN61000-4-2:2009
EMS durability
10V/m (80MHz~1GHz,1KHz80% Amplitude modulation),EN61000-4-3:2006+A1:2010
Applied voltage
9~36V DC
Input connection
DB25
Lower limit of input analog
100mV
Upper limit of input analog
4.95V
Analog conversion accuracy
0.5%
Switching level rule
TTL
Output connection
RS232、RS485、RS422、CAN2.0、USB2.0, an be selected individually or in combination. See the Selection Table for combination.
Communication protocol
See the Model Selection Table to support customization.
Message